Kbiotech — Swiss company
DownloadsContactsTalk to an engineer →
Sheet C.00Core softwareBioFlex™
Home/Core software/BioFlex™
BioFlex™ · bioprocess automation & control software

The process
lives in the
software.

BioFlex™ is not only a supervisory software but a full process automation environment built for bioprocessing: deterministic control, high-resolution data, advanced logic and seamless interaction between hardware, software and process operators.

Request a demo →
Fig. C.1 — Hybrid PLC / SCADA architectureISA 88 / ISA 95
12 – 24Bioreactors in parallel
100 – 500 msLogging interval
Sub-secondMulti-loop closed-loop control
21 CFR 11GAMP 5 · ISA 88 / 95
Sheet C.01Process control

Keeping the culture under control.

01

Multi-loop control

Closed-loop control of pH, DO, temperature, pressure, level and biomass with sub-second response.

02

High-frequency data

Acquisition down to milliseconds on the controller, depending on configuration.

03

Deterministic sequences

Critical phases — inoculation, induction, feeding, CIP/SIP — executed by the PLC, not the PC.

04

Distributed management

Multiple bioreactors and auxiliary systems managed as one process.

Sheet C.02Architecture

One architecture, four plant sizes.

The hybrid architecture keeps deterministic control on industrial PLCs and puts recipes, data and visualisation in the supervisory layer. The same operator interface runs at every scale — which is what makes scale-up a software task.

  • Field to businessFrom sensors and actuators up to MES and ERP.
  • Modular by designFault isolation and scalability for regulated plants.
  • Same HMI at every scaleOperators and recipes carry over.
  • Sterilisation automationSIP/CIP as validated phases.
Automation pyramid · by plant size
BenchtopBiobook I/O · 4 – 12 vesselsBioFlex™ Standard on 15.6″ HMI or PCParallel loops, DoE, gravimetric feeding
R&DKB-BIO-SIP up to 150 LBioFlex™ Standard · industrial PLCSIP/CIP sequences, recipes, KG-Ferm
Pilot / Production200 – 1,000 LBioFlex™ SCADA · Siemens or Rockwell PLCHistorian, batch records, media & steam skids
Industrial> 1,000 LSCADA Manufacturing · redundant PLCGMP module, EU Annex 11, MES / LIMS / ERP
Sheet C.03Software & HMI

See the software at work.

Interactive · pick the master channel, select a slave, drag the points or the test PID output

Live · click 1 / 2 / x to move a channel between axes · layout and time buttons on the toolbar

BioFlex™ — Batch Mode Window
1Pre-SIP check
2SIP 121 °C · F₀ ≥ 12
3Media transfer · gravimetric
4Batch · DO cascade
5Fed-batch · μ-set exponential
6Harvest · CIP
Set-points protected after start · admin override with e-signatureStart batch
Sheet C.04Advanced control

Algorithms that follow the biology.

BioFlex™ organises control hierarchically: master parameters (pH, DO, ORP, biomass, temperature, pressure) drive slave actuators (pumps, valves, gas flows, agitation, heating and cooling). The result is a bioreactor that adapts to biological variability in real time instead of waiting for an operator.

  • Dynamic pH controlTwo-sided control with base and acid pumps, configurable dead-band and CO₂ sparging as an alternative actuator — dosing profiles adapt to buffer capacity.
  • DO cascadeMaster/slave cascade on stirrer → air → O₂ enrichment → back-pressure, with polygonal actuation of up to 5 actuators per loop.
  • Feed strategiesExponential μ-set feed, linear and DO-stat logic, gravimetric dosing on load cells — feed follows the culture, not the clock.
  • Adaptive PIDAuto-tuning based on process response, anti-windup and multi-actuator distribution for stable cultures under dynamic load.
  • EstimatorsCalculation engine for kLa, specific growth rate μ, OUR, CER and RQ — engineered variables usable as control inputs.
  • Biomass predictionPrediction algorithms based on spectroscopy or off-gas data, feeding forward into substrate addition.
Sheet C.05Hardware

Industrial hardware, certified panels.

ControllersIndustrial PLC — Siemens or Rockwell; redundant PLC on industrial systemsPLC
Control panelsBuilt and certified to UL 508A (UL file E554925) · CEUL
HMI15.6″ touch screen on skid, or Windows 10 / 11 workstationHMI
I/O4 digital inputs + 4 outputs per vessel, 0 – 10 V / 4 – 20 mAI/O
Field devicesOptical / polarographic DO, multi-wavelength biomass, load cells, MFC, VFD and servo drivesFLD
SafetyInterlocks at PLC level, hardware watchdogs, emergency shutdown sequencesSAF

Sensors & actuators

  • Continuous monitoringValidation and calibration status, drift detection and redundancy checks on every device.
  • Calibration dataRead and managed in BioFlex™, with audit trail.
  • Third-party devicesAnalog and digital I/O, OPC connectivity.
  • RetrofitBioFlex™ can be installed on existing bioreactors.
Sheet C.06Interfaces

Open to the plant and the enterprise.

OPC UA / OPC DAStandardised integration of analyzers and third-party equipmentOPC
Modbus TCP · Ethernet/IPReal-time signals from skids, drives and instrumentsBUS
SQL historianData exchange with MES, EBR, LIMS and ERP systemsSQL
Data exportCSV / Excel / PDF; MATLAB, Python and JMP readyEXP
Remote accessEthernet and remote diagnostics for serviceRMT
Sheet C.07Data integrity

Records an auditor accepts.

  • 21 CFR Part 11Tamper-proof audit trail, electronic signatures, time-stamped records.
  • GAMP 5Validation packages: URS, FDS, DQ, IQ, OQ, PQ — computerised system validation.
  • ISA 88 / ISA 95Batch and enterprise integration models.
  • EU Annex 11GMP module on industrial systems.

Logging & users

  • High-resolution logging100 – 500 ms intervals; raw, filtered and engineered values.
  • No data lossRedundant buffering on network loss, automatic historian synchronisation.
  • User managementMultiple access levels, session timeout, time-limited profiles, password renewal.
  • RetentionGMP-compliant record retention and secure backups.
Sheet C.08Editions & downloads
StandardSCADA Manufacturing
Intended useR&D, process development, laboratoryLarge-scale production, analytics
DatabaseData logging and exportHistorian, batch records, advanced database
Parallel units12 – 24 bioreactors per station
Compliance21 CFR Part 11 audit trail and e-signatures · OPC-compatible
Sheet C.09Request

See BioFlex™ running your process.

Ask for a remote demo, a licence quote, or a retrofit on existing bioreactors.

+41 916 300 116
info@kbiotech-sa.com
Mon–Fri 8:00–18:00 CET

We reply with a configuration review — not a generic catalogue.